ETCR007AD AC/DC Clamp Leakage Current Sensor
ETCR007AD AC/DC Clamp Leakage Current Sensor ETCR007AD ETCR

Clamp CT: Φ7mm, Range: 0mA~60A (AC/DC), Resolution: 1mA, Power supply: 9VDC, output:10mV/A,100mV/A, Accuracy 3%, Hall effect, Suitable for small spaces AC / DC leakage current, low current test.

ETCR007AD AC/DC Clamp Leakage Current Sensor
产品产商:
会员价格:0.00
服务:售前咨询电话:400-880-5151
产品文档: No Related Documents
如果您对该产品感兴趣的话,可以
ETCR007AD AC/DC Clamp Leakage Current Sensor
Ⅰ. Introduction

ETCR 007AD AC/DC Clamp Leakage Current Sensor is designed for measuring AC/DC current and leakage current under 600V line voltage, by adopting the latest CT technology and digital integrate technology. The small clamp is suitable for line densely places (electric power measurement system, the high speed rail system, car circuit overhaul, and so on), non-contact measurement, to ensure safe operation. It is small, with high precision, stable performance, can be connected with phase detection analyzer, industrial control equipment, data recorder, oscilloscope, electric power quality analyzer, high precision multi-meter. The sensor is widely applied in those fields as electricity, communications, meteorology, railroad, car industry, oilfield, construction, measurement, scientific & research teaching institutes, industrial and mining establishments.
 
Ⅱ. Technical Specifications
             Function
Measurement of AC/DC current, leakage current
Power Supply
Zn-Mn dry battery, 6RL61, 9V. Continually using for 100 hours, connecting external power supply is also available for long time using.
Test Mode
Clip-on CT, non-contact measurement
Clamp Size
Φ7mm
Input Range
0mA-60.0A AC/DC
Output Voltage
10mV/A;100mV/A(corresponding)
Output Range
1V peak max
Resolution
1mA AC/DC
Accuracy
±3%FS(23℃±5℃, below 5%rh)
Phase Error
≤3°(AC 50Hz/60Hz; 23℃±2℃)
Calibration
Adjust ZERO to calibrate, eliminate external electric field interference
Output Wire
Core wire: signal positive output; shielding wire: signal ground
Lead length
2m
Dimension
LWH: 168mm×65mm×34mm
Frequency
AC: 45Hz-400Hz
DC: DC-100kHz
Test Position
Tested wire in the jaw center
Line Voltage
AC600V
Weight
170g (Including the battery)
Working Current
5mA
Working Temperature and Humidity
-10℃-50℃,below 80%rh
Limit Temperature Error
-10℃-0℃ and 40℃-50℃, within 2%rdg
Storage Temperature and Humidity
-10℃-60℃,below 70%rh
Insulating Strength
AC3700V/rms (between the alloy of the clamp and the housing)
Applicable safety rules
IEC1010-1, IEC1010-2-032, Pollution level 2, CAT Ⅲ(600V)
Accessories
Sensor: 1piece; Battery(6F22,9V): 1piece; User Manual/Warranty card/ Certification: 1 copy

 
. Structure Drawing

ETCR007AD AC/CD leakage clamp current sensor

1. Clamp mouth (φ7mm)                               2. DC current positive input indication 

3. Clamp (slender shape)                               4. Toroid opening lever

5. Power indicator                                         6. Signal positive output

7. Signal ground                                           8. Output lead wire

9. ZERO key                                                10. Power / shift switch key   

11. Battery cover screw (1 piece)                 12. Battery cover

13. Housing screws (3 pieces)                     14. Pendant hole

Copyright@ 2003-2019  Guangzhou ETCR Electronic Technology Co., Ltd..  All rights reserved.     

ETCR Electronic Technology Company

Add: No.8, Yongxing He Xingdong Street, Taihe Town,Baiyun District,Guangzhou,China. Tel: +86-020-62199556     Fax: +86-020-61100822   E-mail: info@etcr.cc